In put voltage. | 230 / 110 V AC. +/- 15%. |
Out put voltages. | a) 0 – 30 V DC adjustable. b) 0 – 30 V DC adjustable DUAL. c) 0 – 60 V DC adjustable. d) 0 – 100 V DC adjustable. e) 0 – 300 V DC, 100 ma. |
Out put current. | Up to 0 – 2A / 5A / 10A. |
Characteristic. | CCCV type. |
In put regulation. | 0.1% for 20% variation at input voltage. |
Out put voltage regulation. | 0.01 % for 0 to 100 % load variation. |
Out put current regulation. | 0.1% for load variation. |
Ripple. | Less than 10 mv peak to peak. |
Led indication | For cc and cv modes. |
Course and Fine controls. | Variable smooth controls for 0- 90 % of Total voltage range and 10% variable Control for balance range. |
Course and Fine controls | Settable variable control for current range. |
Voltage / Current meters. | 3 ½ digit voltage meter ( for single/dual PS) 3 ½ digit current meter (For single / dual PS) |
Accuracy of meters. | 0.1% of FSD. |
Out put terminals. | On separate banana terminals. |
Ground. | Floating on separate terminal. |
Insulation. | 500 V from out put terminals to ground. |
Dimension. | 19 “ rack / 115 x 150 x 300 mm max. |